Affiliate disclosure: this site earns a commission from purchases made through links on our pages, including links to Amazon and other retailers, at no extra cost to you. Commissions do not affect our recommendations.
Last updated: 21 November 2026
Short answer
Yes. A CPAP machine is a small load: a ResMed AirSense 11 draws 56 W typical and 73 W maximum, or about 448 Wh for an 8-hour night at the typical figure and 584 Wh a night at the maximum. Even a small 768 Wh station covers about four nights at the typical draw, or about three nights at the maximum.
As a rough guide, plan on the 73 W maximum, not the 56 W typical figure, especially if you use a heated humidifier or heated tubing. Then pick a station that covers the nights you need, and a panel that puts a night’s energy back each day if the outage lasts.
This guide is not medical advice. A CPAP machine is medical equipment. Talk to your doctor or your CPAP supplier about backup power for your treatment, and do not rely on a single battery for equipment your health depends on.
How much power does a CPAP machine use?
| Figure | Value | Source |
|---|---|---|
| Typical draw | 56 W | SolarGenAdvisor appliance wattage chart (ResMed AirSense 11, ResMed datasheet) |
| Maximum draw | 73 W | SolarGenAdvisor appliance wattage chart (ResMed AirSense 11, ResMed datasheet) |
| Hours per night | 8 h | Standard planning figure for a night’s sleep |
| Energy per night (typical) | 56 × 8 = 448 Wh/night | Arithmetic from the rows above |
| Energy per night (maximum) | 73 × 8 = 584 Wh/night | Arithmetic from the rows above |
Your machine’s draw depends on your pressure setting and whether you use a heated humidifier or heated tubing, both of which raise the draw above the 56 W typical figure. We have no separate verified figure for the humidifier’s extra draw, so this guide does not give one: plan on the 73 W maximum and check your own machine’s label. Different CPAP models draw different power, the figures above are for the ResMed AirSense 11, the model the wattage chart cites; if your machine is a different model, check its label and use our sizing calculator with your own watts.
How many nights will a station run a CPAP?
Runtime is a rough guide, calculated as station Wh × 0.85 ÷ watts, then divided by 8 hours to give nights (the 0.85 factor is a planning allowance for inverter and conversion losses, from SolarGenAdvisor’s wattage chart). It assumes the CPAP is the only load.
| Station | Battery | Nights at 56 W typical (rough guide) | Nights at 73 W maximum (rough guide) |
|---|---|---|---|
| BLUETTI AC70 | 768 Wh | About 4 nights (35 hours) | About 3 nights (27 hours) |
| BLUETTI Elite 100 mini | 1,004.8 Wh | About 5 nights (46 hours) | About 4 nights (35 hours) |
| EcoFlow DELTA 3 (original) | 1,024 Wh | About 5 nights (47 hours) | About 4 nights (36 hours) |
| BLUETTI Elite 100 V2 | 1,024 Wh | About 5 nights (47 hours) | About 4 nights (36 hours) |
| EBL EB1000 | 999 Wh | About 5 nights (46 hours) | About 4 nights (35 hours) |
| EcoFlow DELTA 3 1500 | 1,536 Wh | About 8 nights (70 hours) | About 6 nights (54 hours) |
| EcoFlow DELTA 2 Max | 2,048 Wh | About 11 nights (93 hours) | About 8 nights (72 hours) |
| BLUETTI AC200L | 2,048 Wh | About 11 nights (93 hours) | About 8 nights (72 hours) |
| BLUETTI Elite 300 | 3,014.4 Wh | About 17 nights (137 hours) | About 13 nights (105 hours) |
| EcoFlow DELTA Pro 3 | 4,096 Wh | About 23 nights (187 hours) | About 17 nights (143 hours) |
Station specifications are from our verified Solar Match dataset (19 stations, checked against manufacturer pages). Full reviews: BLUETTI AC70, EcoFlow DELTA 3 1500.
The practical minimum is the smallest station in our list. At 56 W, even the 768 Wh AC70 covers about four nights, more than most outages last. A CPAP is one of the few loads where a small, light station is genuinely the right answer, and a big station is only needed if you are also running a fridge, lights or a laptop from the same battery. A CPAP has no start-up surge to worry about: 56 W running means 56 W at start-up, and every station in our list covers it easily.
What solar panel keeps a CPAP running?
A night of CPAP takes 448 Wh at the typical draw (584 Wh at the maximum), so the panels must generate at least that much each day to keep it going indefinitely. Daily solar generation is a rough guide: panel watts × 4.0 peak sun hours × 0.85.
| Pairing | Daily solar (rough guide) | Covers a night’s CPAP? | Verified |
|---|---|---|---|
| BLUETTI AC70 + 2× ZOUPW 100W Portable in series | 200 × 4.0 × 0.85 = 680 Wh/day | Yes, covers a 448 Wh night, and most of a 584 Wh night | Passes all Solar Match checks |
| BLUETTI AC70 + 2× BLUETTI SP100L in series | 200 × 4.0 × 0.85 = 680 Wh/day | Yes, covers a 448 Wh night, and most of a 584 Wh night | Passes all Solar Match checks |
| EcoFlow DELTA 3 (original) + Jackery SolarSaga 200W | 200 × 4.0 × 0.85 = 680 Wh/day | Yes, covers a 448 Wh night, and most of a 584 Wh night | Passes all Solar Match checks |
| BLUETTI AC70 + 1× EcoFlow 110W Portable | 110 × 4.0 × 0.85 = 374 Wh/day | No, 74 Wh short of a typical night | Passes all Solar Match checks, but not enough watts |
| BLUETTI AC70 + 1× ZOUPW 100W Portable | 100 × 4.0 × 0.85 = 340 Wh/day | No, 108 Wh short of a typical night | Passes all Solar Match checks, but not enough watts |
Recharge time, as a rough guide, is station Wh ÷ (panel W × 4.0 × 0.85). The AC70 (768 Wh) with 2× 100 W panels in series recharges from empty in about 1.1 days of sun; with a single 100 W panel it takes about 2.3 days. Check any other station-and-panel combination in Solar Match before you buy, voltage, current and connector must all fit, not just watts.
Two panels that do NOT fit the AC70, even though the watts look right: the Jackery SolarSaga 200W and the EcoFlow 160W Portable both fail the AC70’s 10 A solar current check (their short-circuit current × 1.25 safety margin is 14.0 A and 12.0 A). Same watts as a passing combination, wrong current. This is exactly what Solar Match checks for, and why a 2× 100 W series pairing works where a single 200 W panel does not.
Safety: CPAP, bedrooms and outages
A battery power station makes no exhaust, no carbon monoxide and no fumes, so it is the only kind of generator that is safe to run indoors, including in a bedroom while you sleep, in a dry room with its vents clear. Every gas, propane or dual-fuel generator must stay outside, at least 20 feet from the house, never in a home, garage, basement or shed, the US Consumer Product Safety Commission rule cited in SolarGenAdvisor’s indoor-safety guide.
Three practical notes for CPAP users. First, keep the station charged before an outage is forecast, a CPAP night is only 448 Wh, but an empty station helps no one. Second, test the setup before you need it: run one full night on the station at home, with the humidifier setting you actually use, and see how much battery is left in the morning. Third, have a fallback: keep your mains charger and, if your supplier offers one, a 12 V car adapter for the CPAP. A battery station is a backup, not a replacement for your treatment plan, if your health depends on the machine working every night, talk to your doctor or supplier about what happens if the backup fails too.
Which station to pick for CPAP
A CPAP is one of the few loads where a small station is genuinely the right answer, because there is no start-up surge to worry about and a night takes only 448 Wh at the typical draw.
- Travel or a short outage: the smallest station in this guide, the BLUETTI AC70 at 768 Wh, covers about four nights at the typical draw, or about three nights at the 73 W maximum. Pick it if you want the lightest station that still covers several nights.
- A week or more: a 1,536 Wh station, the DELTA 3 1500 class, covers about eight nights at the typical draw, or about six at the maximum. Add 200 W of panels and the sun puts a night’s energy back each day, so the setup keeps going indefinitely in good sun.
- CPAP plus other loads: if the same station also runs a fridge, lights or a laptop, size it for those loads instead. A fridge needs about 1,200 Wh a day on its own, far more than a CPAP night, so the fridge decides the station size, not the CPAP.
Our pick for most CPAP users is a 768 Wh to 1,024 Wh station with 200 W of panels: light enough to keep by the bed, enough battery for several nights, and enough solar to refill a night’s use each day. Test the setup before you need it: run one full night on the station at home, with the humidifier setting you actually use, and see how much battery is left in the morning. Keep your mains charger and, if your supplier offers one, a 12 V car adapter as a fallback.
Limits of this guide
The wattage figures in this guide are for the ResMed AirSense 11, the model the wattage chart cites. Other CPAP models draw different power, so check your own machine’s label and use our sizing calculator with your own watts. We have no separate verified figure for a heated humidifier’s extra draw, so this guide does not give one: plan on the 73 W maximum. This guide is not medical advice. A CPAP machine is medical equipment, so talk to your doctor or your CPAP supplier about backup power for your treatment, and do not rely on a single battery for equipment your health depends on.
How we checked
All station specifications (battery Wh, AC output, surge, solar input, voltage range, current limit) come from our Solar Match dataset of 19 stations and 19 panels, verified against manufacturer pages and manuals. CPAP watts come from the SolarGenAdvisor appliance wattage chart (ResMed AirSense 11: 56 W typical, 73 W maximum, sourced from the ResMed datasheet). Every runtime and recharge figure is arithmetic labelled “rough guide”, a planning estimate, not a measurement. We have not physically tested these stations with a CPAP machine. Our full method, including the ten compatibility checks, is on our Methodology page. No prices are listed: prices change often, and we do not publish a price we have not verified as current. Weights are not listed: our catalogue does not publish verified weights.
Related guides
- Can a solar generator run a fridge?, 1,200 Wh/day, a much bigger load than a CPAP
- Can a solar generator run a freezer?, 800 Wh/day
- Can a solar generator run Starlink?, 2,160 Wh/day for Standard, 720 Wh/day for Mini
- Best solar generator kits for camping, light kits that cover a CPAP night outdoors
- Best solar generator kits for home backup, 4 verified station-and-panel kits for outages
- What size do I need? sizing calculator, work out CPAP plus your other loads
- Compare stations side by side, battery, output and solar input for all 19 stations