T9 Solar Match: Solar Compatibility Checker

Complete-product compatibility

T9 Solar Match Tools

Select the complete power station and solar panels you're planning to use in your solar system. The Solar Match tool compares their key specifications and highlights potential compatibility issues before you build your system.

Build your system

Step 1 · Your setup
kWh / day
Peak load (W) — optional
W at once
The most power you will draw at once (largest appliance, or all appliances running together).
Peak sun hours / day
h/day
Drives the recharge-time check only.

Power Station

Battery, inverter and charge controller in one unit
Verified manufacturer specifications only

Solar panels

Portable panels from the same catalogue
Verified manufacturer specifications only

System compatibility

Checks run only on published data — an incomplete setup never shows 100%.
Waiting for your setup
0 / 4
checks ready
0 Failed0
4 Not run4
0 Ready0
Pick a power station and solar panels to run the four electrical checks.
System compatibility
0% match
Counts only the 4 electrical checks
Solar input voltage
Pick a panel and a station.
Pending
Solar input current
Pick a panel and a station.
Pending
Solar input power
Pick a panel and a station.
Pending
Autonomy / capacity
Enter your daily energy use and pick a station.
Pending
Peak load vs. AC output
Enter your peak load to check the AC output.
Pending
Solar recharge time
Pick a panel to estimate the recharge time.
Pending
Connector & cable
Pick a panel and a station.
Pending

Incompatibilities

    Recommendations

      —
      Array watts
      —
      Array Voc
      —
      Array current
      —
      Autonomy

      Our recommendation

      Real products from the T9 catalogue — nothing generic.

      —

      Pick a station to see our recommendation

      The matched station for your daily use appears here.
        —

        Pick a station to see matching panels

        The panel array that fits your station's solar input appears here.

          How Solar Match evaluates your setup

          Solar Match is a compatibility checker for portable solar systems. It compares the electrical characteristics of a power station, one or more solar panels and the cable between them, then reports where the numbers stop agreeing. Every value it uses comes from manufacturer datasheets held in the T9 catalogue, so the comparison reflects published specifications rather than estimates.

          Step 1 · Describe how you use the system

          You start with three figures: average daily energy use in kWh, an optional peak load in watts, and the number of peak sun hours your location receives. Daily energy use tells the tool how much the battery has to deliver between charges. Peak load is what the inverter has to sustain at once, which matters for kettles, pumps and power tools. Peak sun hours convert panel wattage into a realistic daily yield instead of a laboratory number, and they drive the recharge-time estimate.

          Step 2 · Pick the hardware

          Next you select a power station — a battery, inverter and charge controller in one unit — and one or more portable panels from the same catalogue, with a quantity for each. Panels can be wired in parallel or in series, and the choice changes both voltage and current at the input. The tool recalculates the whole array as you change quantity or wiring, so you can see the effect of adding a second panel before buying it.

          The four electrical checks

          System compatibility runs four checks and reports each one separately. Solar input voltage compares the array open-circuit voltage (Voc) against the station’s accepted input window — too low and the charger never starts, too high and you risk damaging the input stage. Solar input current compares array current against the station’s input current limit. Solar input power compares total array wattage with the maximum solar input the station can accept. Autonomy and capacity compares usable battery capacity against your daily energy use, so you know whether the station covers a full day or only part of it.

          Two further checks run outside the electrical count. Peak load versus AC output tells you whether the inverter can carry your load without tripping, and the connector and cable check flags mismatched connector types and cable runs that would waste power through voltage drop.

          Reading the result

          Each check returns one of three states: ready, failed, or not run. A failed voltage or current check is a hard stop — the system will not charge safely or at all. A failed power check usually means slower charging rather than danger. A capacity shortfall is neither, but it does mean the station will need sun or mains before the day is out. Incompatibilities are listed by name, with the specific figure that caused each one, so you can decide whether to change the panel, change the wiring, or change the station.

          Recommendations tied to real products

          Once a station is selected, Solar Match proposes a station matched to your stated daily energy use, drawn from products that exist in the catalogue rather than generic examples. The recommendation appears with the array watts, array Voc and array current the tool calculated for your configuration, so it can be checked line by line against the datasheets.

          What it does not do

          The tool compares published specifications. It does not measure your hardware, predict weather, account for shading, cable temperature or panel degradation, and it does not replace the manufacturer’s manual. Treat a green result as a sign that the numbers agree, not as a guarantee of performance. Where a product has no verified specification on file, it is left out of the comparison rather than guessed.