How we review

Last updated: 21 November 2026

Wild Energy Tech publishes research-based guides to portable power stations and solar panels. We check manufacturer documentation, verify specifications against our own tools, and say plainly what we did and did not do. This page explains exactly how a recommendation on this site was made, and how you can check it yourself.

What we do not do

We have not physically tested the products on this site unless a page is labelled Hands-On. Our analysis is documentation-based: manufacturer manuals and official specifications, checked against our Solar Match compatibility data. We do not present manufacturer marketing copy as independent testing. We have no test lab, no review units, and no field-testing programme, and we do not claim otherwise anywhere on this site.

How we verify a specification

Every specification on this site goes through the same steps. Each step is a check you could repeat yourself:

  1. Manufacturer first. We pull the specification from the manufacturer’s own product page or manual first. A retailer listing alone is never the source.
  2. The fields that decide compatibility. For a power station we check capacity (Wh), AC output and surge (W), solar input power (W), solar input voltage range (V), maximum solar current (A) and connector type. For a panel we check rated power (W), open-circuit voltage Voc (V), operating voltage Vmp (V), short-circuit current Isc (A) and operating current Imp (A).
  3. Cross-check against our tools. The same figure is checked against the verified station and panel data in our Solar Match tool (19 stations and 19 panels, version 2.1.0, November 2026), and against the sizing calculator and comparison tool where the same figure is used. One dataset, three tools, updated together.
  4. If it was not published, we say so. Where a specification was not published, for example, the connector of the BLUETTI SP100L, or the exact BLUETTI 350W panel variant, we say so and do not guess. A dash (-) in our data means “not in our verified data”, never “does not have it”.
  5. We record the check date. Every guide states its own check date, in this form: “All specifications in this guide were checked against manufacturer pages and manuals, and against the verified station and panel data in our Solar Match tool, on [date].” This page states the rule; each article states its own date.
  6. Recharge times are arithmetic, not measured. Recharge and generation figures are calculated (4.0 peak sun hours a day, 85% overall system efficiency) and labelled “rough guide” wherever they appear. They are never presented as measured times.

The compatibility checks we actually run

Compatibility on this site is decided by the checks we run, the same checks behind every station-and-panel recommendation. Checks 1–9 are enforced by our Solar Match tool in code; check 10 is verified in every guide and kit recommendation. Each check has a pass condition and a stop condition. A check that fails means “do not connect”, not “maybe”.

  1. Series ban. If a panel’s manual says it must not be wired in series (for example the EcoFlow 45W portable panel), series wiring with more than one panel is a stop. Use one panel, or parallel wiring if the station allows it.
  2. String voltage, maximum. The combined open-circuit voltage (Voc) of the panels in series must stay at or below the station’s maximum solar input voltage. Above it: do not connect.
  3. String voltage, minimum. The combined operating voltage (Vmp) of the panels must stay at or above the station’s minimum solar input voltage. Below it, charging may be weak or not start. Where the manufacturer never published a minimum voltage, for example the EcoFlow DELTA 3 Max 2048, the check passes on the maximum only, and we say that charging start is not verified.
  4. Panel current, operating. The panels’ operating current (Imp) must stay at or below the station’s maximum solar current. Above it: do not connect.
  5. Panel current, safety margin. The panels’ short-circuit current (Isc) multiplied by a 1.25 safety margin must stay at or below the station’s maximum solar current. Close to the limit, we flag it for review.
  6. Total solar power. The panels’ combined wattage must stay at or below the station’s maximum solar input. Above it, the output is clipped, the station takes only what it can use, so we flag it and suggest fewer or smaller panels.
  7. Autonomy. The station’s battery capacity (Wh) is divided by your daily consumption (Wh per day). The result is the share of a full day the station covers. Below half a day, it is not enough for that use; between half a day and a full day, we say so and suggest more capacity.
  8. AC output. When you enter your biggest appliance (W), the field is optional, it must fit the station’s continuous AC output (W). Above it, the appliance may not run, or may trip the station.
  9. Estimated peak load. If you have not entered a biggest appliance, we warn when the station’s AC output is below roughly three times your average draw, because real loads peak above the average. This is an estimate only, not a measured load. Enter your biggest appliance for a real AC check.
  10. Connector + polarity. The panel’s connector must fit the station’s solar input, directly, or through the correct manufacturer-approved adapter cable, and the polarity must be correct. A plug that fits is not proof of compatibility: the wrong cable can limit charging (on EcoFlow stations, the XT60i third pin tells the station what is connected), and reversed polarity can damage the station. This check is applied in every guide and kit recommendation on this site, from the same verified dataset (the connector is recorded for every station and panel). The Solar Match tool enforces checks 1–9 in code; this check will be added to the tool next.

A note on the name: our About page has called this method the “T9 Ten-Gate Compatibility Method”. That name promises ten gates, and the list above now has ten checks. Checks 1–9 are enforced by the Solar Match tool in code; check 10 (connector + polarity) is verified in every guide and kit recommendation on this site, from the same verified dataset. We do not invent checks to fill the name, every check above is one we actually run.

How we choose what to recommend

  • “Best” always means “best for a stated use.” Best for camping, best for home backup, best under $500, best as a kit, never “best overall” without context. A product that is right for home backup can be wrong for camping, and we say which use we mean.
  • Only verified specifications get listed. A product is listed only where its specifications are verified from the manufacturer. Four products stay excluded until an official source confirms the missing solar input current (Isc): the EBL Acc2400, the GRECELL H2400, the AFERIY P180, and the GRECELL SP-200 panel. We do not invent the missing value.
  • We do not give scores. No scores, no star ratings, no ranked formula. A score would need a published formula and data we do not have for every model.
  • Some fields we do not verify. Our verified dataset does not include weights, warranty terms, cycle life, UPS switchover times, charge times or port details for every model, so we do not publish those fields, and we do not rank products on them. If a field is missing, the reason is that it is not in our verified data.

How we check prices

Prices are checked live on the manufacturer’s own store, or on the named retailer, with the source store and the check date recorded for each price. A price that cannot be verified is not shown. Our catalogue currently lists 116 products. Where a price is shown, the card records the source store and check date. Prices are re-checked after sales events and we never carry a stale price forward. No prices are printed on this page; it states the rule only.

How we make money

We earn a commission if you buy through links on this site, at no extra cost to you. Commissions never change what we recommend. We do not accept payment for positive reviews. Read the full Affiliate Disclosure for the details.

Who writes and who reviews

Every guide on this site is written and reviewed by Cledenir de Souza, who runs Wild Energy Tech from Lisbon, Portugal. Articles are drafted with AI assistance, then checked through our internal review steps, an editorial check, a claims-and-sources check, and a law-and-disclosure check, and published only after human approval. There is no second reviewer and no guest author: one real person is accountable for everything published here.

How often guides are updated

Guides are re-checked when a specification, a price or a product changes. The “Last updated” date on a page changes only when its content really changes, we do not change dates to make a page look fresh. A material correction gets a note on the page itself and a date change. Corrections are invited: write to contact@t9wildenergy.com. See our Editorial Policy for the corrections policy and a list of what we have fixed.

What this site is not

We are not electricians and we do not offer electrical installation advice. Our guides are supplementary and do not replace official documentation. Always check the manufacturer’s manual before connecting anything, and if you are unsure, ask a qualified electrician. Read our Safety Disclaimer before you connect a panel to a station.

What we do when sources disagree

Manufacturer pages, manuals and retailer listings do not always agree. When they disagree, the manufacturer’s own manual comes first, then the manufacturer’s product page, then a retailer listing, which is never the source on its own. Where two official sources give different figures for the same model, we publish the figure we can trace to a document, and we say that the other figure exists. Where a figure cannot be confirmed at all, we do not publish it as fact. Two examples on this site are the EcoFlow DELTA 3 Max Plus, where the US manual allows 18 A of solar current and the EU rating is not confirmed on EcoFlow’s EU page, and the Jackery SolarSaga 200W panel, where the Isc figure of 11.2 A comes from our tool data only and is flagged wherever it appears. A disagreement that changes a recommendation is noted on the page itself, with the date of the correction.

Safety checks in every recommendation

Every station and panel pairing on this site passes the same safety checks before we recommend it. The panel’s Voc must sit inside the station’s solar voltage range, its Isc must be at or below the station’s maximum solar current, and its watts must be at or below the station’s maximum solar input. A pairing that fails any of these checks is a do-not-connect pairing, not a maybe. We also check the connector, because a panel with no adapter for the station cannot be used with it at all. We are not electricians and we do not offer electrical installation advice, so our guides are supplementary and do not replace the manufacturer’s manual. Always check the manual before connecting anything, never connect a station’s AC output to household wiring or the grid, and if you are unsure, ask a qualified electrician.

Links