What size do I need?
Pick your appliances and we do the sizing.
Pick your appliances → we size the battery, inverter and panels.
Disclosure: We may earn a commission if you buy through links on this page, at no extra cost to you. Commissions do not affect our recommendations.
Your inputs stay in your browser. Nothing you enter is sent to us or stored.
1. What do you want to power?
Tick the appliances, set watts, hours per day and quantity. Watts are typical. Check the label on your appliance (watts = volts × amps). You can overwrite any typical watt value with the watts from your own appliance label.
Fridge / freezer use an 8-hour duty cycle (they cycle on and off, so they do not draw full power for 24 h). Starlink and the Wi-Fi router default to 24 h because they run all day. All loads are treated as AC in this version. See "How we calculate".
2. Your situation
Days of autonomy (backup)
1 to 3 days. 1 day = overnight / outage; 3 days = longer emergency run.
Peak sun hours per day
2 to 6. Adjust for your region and season. See the EU note below.
Only needed if you have one big load that is not in the picker above (for example a power tool). If it is bigger than everything you ticked, the inverter size uses this value instead.
EU note: Mains voltage here is 230 V (EU/UK). EU kettles are typically 2,000 to 3,000 W, not 1,500 W. Check your appliance label. Peak sun hours vary by location; adjust the input for your region.
2. Pick a station
Runtime uses the appliances ticked above. Untick an appliance to leave it out of the table.
3. Your answer
Your answer · rough guide
n/a
Wh per day
n/a
Battery (Wh)
n/a
Inverter (W)
n/a
Solar input (W)
n/a
Panels (200 W each)
Show my math ▾
3. Your answer
Your answer · rough guide
n/a
Tick an appliance to see runtimes
n/a
Usable energy (Wh)
n/a
Battery (Wh)
n/a
AC output (W)
n/a
Appliances ticked
Show my math ▾
Runtime (h) = usable Wh ÷ load W, with usable Wh = battery Wh × 0.85 (about 15% inverter / conversion loss). A load above the station’s AC output shows as “Over limit”. All runtimes are a rough guide.
Matched stations, smallest adequate first
A station matches when its battery is ≥ the recommended battery and its AC output is ≥ the recommended inverter and its surge rating is ≥ the peak. Each matched station shows the panels that fit it (checked the same way Solar Match checks them) and how long those panels take to recharge it, a rough guide.
Runtime per appliance
| Appliance | Load (typical) | Runtime (rough guide) |
|---|
Runtime (h) = usable Wh ÷ load W, with usable Wh = battery Wh × 0.85 (about 15% inverter / conversion loss). A load above the station’s AC output shows as “Over limit”. A starting surge above the station’s surge rating shows a surge warning. All runtimes are a rough guide.
How we calculate
- Daily energy:
daily Wh = Σ (typical running W × hours/day × quantity) - Battery:
battery Wh = daily Wh × days of autonomy ÷ 0.80, rounded up to the next 100 Wh. 0.80 is the usable fraction of a LiFePO4 battery for daily cycling. Note: this leaves out a separate inverter-efficiency allowance. The EcoSolarKits method also divides by 0.92, which would give a battery about 8% larger; v1 leaves that out as a deliberate simplification. - Inverter:
inverter continuous W = Σ running W × 1.2, rounded up to the next 100 W. 20% headroom on everything running at once.Peak W = inverter continuous W + single largest starting surge. Surge values are typical starting watts. Check your appliance; motors and compressors (fridge, freezer, washing machine) surge well above their running watts, most other appliances do not surge. The fridge starting surge used here (1,200 W) is the low end of the typical +1,200 to 2,200 W fridge-start range. At the high end the peak would be up to 1,000 W higher. If you fill in the optional biggest-appliance field and it is larger than the ticked total, the inverter uses that value instead. - Solar:
panel W = daily Wh ÷ peak sun hours ÷ 0.75, rounded up to the next 50 W. The ÷0.75 loss factor covers panel angle, heat, charge-controller and wiring losses. The array is sized to replace one day’s use in one day of sun, not to refill the whole battery. - Runtime:
runtime (h) = battery Wh × 0.85 ÷ load W. Usable Wh = battery Wh × 0.85. - Recharge:
recharge days = station Wh ÷ (panel W × peak sun hours × 0.85), a rough guide. - Worked example: fridge 150 W × 8 h + LED lights 40 W × 5 h + laptop 60 W × 6 h + Starlink 90 W × 24 h + 2 × phone chargers 15 W × 4 h = 1,200 + 200 + 360 + 2,160 + 120 = 4,040 Wh/day. Battery (1 day) = 4,040 ÷ 0.80 = 5,050 → 5,100 Wh, larger than every station in our list (largest is 4,096 Wh), so that load shows the “no station covers this load” state. Inverter continuous = (150 + 40 + 60 + 90 + 30) × 1.20 = 444 → 500 W; peak = 500 + 1,200 (fridge start, low end of the range) = 1,700 W. Solar = 4,040 ÷ 4.0 ÷ 0.75 = 1,347 → 1,350 W.
- Panel checks (same as Solar Match): string Voc ≤ station max solar voltage; string Vmp ≥ station min solar voltage; string Imp ≤ station max solar current; string Isc × 1.25 ≤ station max solar current; total panel W ≤ station max solar input. 1 to 4 panels of one model, series or parallel. The EcoFlow 45W panel must not be connected in series.
Formulas follow the gap-5 research consensus (SolarGenAdvisor, OffGridAuthority, EcoSolarKits, Solar Calculator HQ). The battery divisor 0.80 is the usable LiFePO4 fraction; published sources use 0.80 to 0.90. All figures are planning estimates: actual draw varies by model, age and conditions.
What this tool does not check: battery reserve (BMS cut-off); capacity loss with temperature, age, high discharge or standby draw; how long a surge lasts or whether a motor will actually start; charging and discharging at the same time; panel temperature, tilt, shade, weather or cable loss. This is a planning estimate, not professional engineering.